A-level Physics revision · Measurements and their errors

Uncertainty and errors

The idea

Random errors cause unpredictable scatter between repeated readings; repeating and averaging reduces their effect. Systematic errors shift every reading the same way and are not reduced by repeats. Precision is closeness of repeats; accuracy is closeness to the true value.

  1. Absolute uncertainty: half the range of repeats, or at least the instrument's resolution for a single reading.
  2. Percentage uncertainty =absolute uncertaintyvalue×100%= \dfrac{\text{absolute uncertainty}}{\text{value}} \times 100\%.
  3. Remove systematic errors by checking zero errors and calibration.

Watch out A zero error on a meter is systematic: averaging more readings does not remove it.

See it worked

Worked example

Five readings of a time are 2.31, 2.35, 2.28, 2.33 and 2.33 s. Find the mean and its absolute uncertainty.

  1. Mean =11.60/5=2.32= 11.60/5 = 2.32 s.
  2. Range =2.35−2.28=0.07= 2.35 - 2.28 = 0.07 s.
  3. Uncertainty =12×0.07≈0.04= \tfrac12 \times 0.07 \approx 0.04 s (half the range).

Answer 2.32±0.042.32 \pm 0.04 s

Your turn

Question 1Calculator allowed1 mark

A length is measured as 25.0±0.525.0 \pm 0.5 cm. What is the percentage uncertainty?

Question 2Calculator allowed1 mark

A balance reads 0.02 g with nothing on it. What kind of error is this?

Choose one
Question 3Calculator allowed1 mark

Repeat readings of a current are 0.42, 0.45, 0.43 and 0.46 A. Using half the range, what is the absolute uncertainty in the mean?

In past papers

12 official questions in 11 papers since 2017. The latest:

All A-level Physics past papers

A-level Physics Pro, AQA 7408

A-level Physics Pro

£129 once

Price rises to £199 on 1 January. Save £70 by joining before then.

At least 12 months of access

By paying you agree to our Terms and get access straight away, which ends your 14-day cancellation right.
Start free

No VAT is charged.

Independent practice for AQA A-level Physics (7408), not endorsed by AQA.

Privacy · Terms